Reversible stainless steel plunger with 10mm dia. on one end and threaded, H-3070 1mm dia. stainless steel needle on the other. Weight of plunger assembly with adjustable indicator is 300g. Graduated 0-50mm scale. Includes frame, graduated 0-50mm scale, plunger assembly, H-3080 conical mold and H-3049 glass plate.
H-3150 Gillmore Apparatus
Used to determine initial and final set times of Portland cement, masonry cement, hydraulic hydrated lime and certain mortars. Complies with ASTM standards C91, C141, C150, C266, C414; AASHTO T154. Comprised of two stainless steel needles with 3/16" (4.8mm) cylindrical flat-end needles. One is 1/12" (2.12mm) dia. 1/4lb. (113.4g) weight for initial set. The second is 1/24" (1.06mm) dia., 1lb (453.6g) weight for final set.
H-3240 Cement Autoclave
Uses accelerated means of estimating delayed expansion of Portland cement caused by hydration of CaO and MgO. Test bars are exposed to controlled steam pressure and corresponding constant temperature. Unit produces 60-350 psi range of pressures and consists of steam vessel, pressure regulator, pressure gauge (0-600 psi x 5 psi), air vent valve, power switches and safety pop valve set at 350psi. Includes thermometer, wrench and 5 gaskets.
H-3624 Motorized Flow Table with Counter
Motorized flow table with 10" dia. cast-bronze table/platen and automatic digital counter. Motor stops automatically once pre-set number of drops is achieved. Includes heavy-duty table/platen assembly, standard cast bronze, 2-3/4" top dia. x 2" high x 4" bottom dia. cone mold, motor and counter. Designed to be mounted to concrete mounting block.
Also available as a Hand-Driven Flow Table with Mold (H-3620)
H-3825 Cube Test Ottawa Sand C109
Sand is specially graded natural silica sand graded to retain 98% on a No. 100 sieve, 75% on a No. 50, 30% on a No. 40 and 2% on a No. 30. Specific gravity is 2.65. Packed in 50 lbs. bags. Meets ASTM C87, C109, C348, C359, C593, C778; AASHTO T71, T106, T185.
H-3820 ASTM 20-30 Test Sand
Sand is specially graded natural silica sand to pass a No. 20 sieve. Specific gravity is 2.65. Packed in 50 lb. bags. Meets ASTM C91, C141, C185, C359, C778; AASHTO T132, T137, T185.
H-3630A Water Retention Apparatus
The apparatus is used in specification tests of masonry cement and physical testing of quicklime and hydrated lime. The newly designed unit incorporates a vacuum regulator and gauge system in place of the old mercury manometer and relief column. The complete unit consists of an aspirator pump, vacuum regulator, vacuum gauge, three-way stopcock, flask, rubber gasket, brass funnel, perforated brass dish, filter paper and hardwood stand. Meets ASTM C1506, C110, C207 and E149.
H-3600 Cement Bleeding Apparatus
Used to determine bleeding rate and bleeding capacity of cement paste and mortar by direct and continuous procedure. Includes noncorrosive metal container for paste or mortar, collecting ring, support stand and necessary glassware. Rubber-covered double V-jaw burette clamp holds stopcock in position; single rubber-covered jaw clamp supports the burette and funnel assembly.
H-3810 Blaine Air Permeability Apparatus
Determines fineness of Portland cement in terms of specific surface expressed as total surface area in square centimeters per gram of cement. Consists of: calibrated U-tube manometer, ground glass joint, stainless steel test cell and plunger, rubber aspirator bulb and perforated disc. Includes 8 oz bottle of red manometer fluid, filter paper, wood block for holding test cell during filling and funnel. Mounted on finished wood panel with rubber-footed base. Meets ASTM C204; AASHTO T153.
H-3805 Wagner Turbidimeter
The Wagner Turbidimeter determines fineness of Portland cement, using photoelectric cell to measure light passing through suspended pulverized material. Microamp meter measures current generated in the cell; indicated reading is measure of turbidity of the suspension. Includes photoelectric cell and light source in metal cabinet, timing burette and stand, wet sieving assembly including gauge and spray nozzle, microamp meter, 3 flasks, 4 test tubes, stirring apparatus and instruction book. Battery not included. Meets ASTM C115; AASHTO T98.
H-3160 Cement Calorimeter
Cement Calorimeter for determining heat of hydration of cements by measuring difference between heat of solution of dry cement and heat of solution of a separate sample partially hydrated for 7 to 28 days. Constant-speed stirrer maintains uniform temperature throughout liquid and supplies sufficient agitation to keep solid reactant suspended in the acid mixture. Includes insulated wood case, insulated 1G can; 1 pt. vacuum jar with stopper; differential thermometer plus holder, rod and reading magnifier; glass funnel; stirring paddle and chuck; geared synchronous motor; 4oz. bottle of vinylite paint, and instructions. Meets ASTM C186.
H-3320 Reaction Container
For determining potential alkali reactivity of aggregates (chemical method) when used with high alkali cements. Stainless steel unit is 2" dia. x 2-1/4" high fitted with air-tight cover. 50-75ML capacity. Meets ASTM C289.
H-3840 400ml Measure
Calibrated to 400ml, this measure is used to determine air content of hydraulic cement mortar. Cylindrical with 3" (76mm) ID, approximately 3-15/32" (88mm) depth. ASTM C185, C780; AASHTO T137.
H-3350 Cement Soundness Tester
Mold used to determine soundness of cement by measuring the expansion of cement when heated in an atmosphere of steam or boiling water. It consists of a brass split ring and two long parallel indicating arms. As cement expands, the ring is spread and an increased distance between the free ends of the indicating arms gives an index of soundness.
H-4133 Acme Penetrometer
Hydraulic reaction-type apparatus for determining the setting time of concrete with slump greater than zero by testing mortar sieved from the concrete mixture. It also determines the effects of variables such as temperature, cement, mixture proportions, additions and admixtures upon the time of setting and hardening of concrete. The penetrometer’s design makes it easy to operate, being more efficient, with a longer gear rack. All needles are one length so settings may remain the same. Loads are applied hydraulically with pressures read on a 200 lbf capacity gauge graduated in 2 lbf divisions. Set of six needles allows multiplication to a maximum reading of 8000 lbf. The Acme penetrometer features cast aluminum base and set of stainless steel penetration needles in a wooden block (bearing area: 1, 1/2, 1/4, 1/10, 1/20 and 1/40 sq. in., (645, 323, 161, 65, 32 and 16mm2). Includes 100 laboratory test data reporting forms. Meets ASTM C403; AASHTO T197.